阿拉上海后花园论坛

Service hotline:
 Universal banner
Your current location: home page > Hot information

contact us Contact Us

Shandong Lanyue Photoelectric Technology Co., Ltd

400 Tel: 400-6432-167

Mobile number: 18866000049

Fixed telephone: 0534-7281003

Fax No.: 0534-7281007

QQ:202519309/ eighty-one million five hundred and twenty-four thousand four hundred and fourteen

mail box: [email protected]

                [email protected]

Address: Dezhou (Yucheng) High tech Industrial Development Zone, China

Zaozhuang professional city circuit lamp manufacturer

2020-12-16
 Zaozhuang professional city circuit lamp manufacturer

(1) Recommended installation height of 50W LED energy-saving mining lamp: 3-5 meters; Installation distance: 5-8m. (2) Recommended installation height of 100W LED energy-saving mining lamp: 6-8m; Installation distance: 8-10 m. (3) 120W LED energy-saving mining lamp Recommended installation height: 8-10m; Installation distance: 8-10 m. (4)150W major City circuit lamp Recommended installation height: 10-15m; Installation distance: 8-12m. (5) major City circuit lamp 200W Recommended installation height: 10-15m; Installation distance: 10-15m. (6) LED energy-saving mining lamp 300W recommended installation height: 15-20m; Installation distance: 20-25m. (7) Recommended installation height of 450W LED energy-saving mining lamp: 15-20m; Installation distance: 25-30m

 Zaozhuang professional city circuit lamp manufacturer

1、 Disconnection. For "dead light", we should first determine major City circuit lamp Is it short circuit or open circuit. 2、 The adhesive layer is peeled off. For some LED energy-saving project lights with vertical chips, the common reasons for dead lights are the peeling off of the bottom of the chip bonding layer and the peeling off of the bracket coating. 3、 The welding spot is burnt. In some cases, the dead light of the bulb may not be caused by the bulb itself, but also by the power supply used. 4、 Chip corrosion. The previous energy-saving floodlights and energy-saving floodlights are open circuit. The following is the condition of short circuit dead light. major City circuit lamp There are many reasons for dead lights. Dead light may appear in every link from packaging, application to use.

 Zaozhuang professional city circuit lamp manufacturer

The power supply of LED project lights is high-voltage alternating current. During installation, please keep away from the place that is easy to access, and properly ground the lamps to avoid electric shock accidents. When wiring, the installation personnel shall select the appropriate power line according to the power of the bulb actually used, and separate the power supply to avoid affecting the normal use of flood lights. major City circuit lamp It is designed to be waterproof and moisture-proof, and its protection grade can reach IP65. It can withstand the test of rain, but cannot work underwater, and its protection level cannot meet the requirements of underwater work. major City circuit lamp The installation position of shall be able to bear the weight of the projection lamp, and its bearing capacity shall be 10 times greater than the weight of the projection lamp, so that the lamp can be firmly installed and the danger of falling in the future can be avoided.

 Zaozhuang professional city circuit lamp manufacturer

The life of LED mining lamp depends largely on the level of heat dissipation, and the main way to improve the level of heat dissipation is to transfer the excess heat generated by the chip through the radiator and radiator. At the same time, major City circuit lamp The main parameters related to LED heat dissipation are thermal resistance, junction temperature, temperature rise, etc. Thermal resistance is the quotient obtained by dividing the difference between the effective temperature of the equipment and the temperature of the external designated reference point by the steady-state power consumption in the equipment. It is an important parameter indicating the degree of heat dissipation of equipment. Junction temperature refers to the temperature of the semiconductor junction of the main heating part in the LED device. It reflects major City circuit lamp Temperature value that can be withstood under working conditions. Temperature rise refers to the temperature rise of the enclosure environment. It refers to the difference between the temperature of LED equipment shell and the ambient temperature. This is a temperature value that can be directly measured, which can directly reflect the heat dissipation degree around LED devices.

 Zaozhuang professional city circuit lamp manufacturer

install major City circuit lamp The construction site shall be provided with safety slogans, warning signs and safety operation instruction boards, which shall not be removed or moved at will. Any movement shall be approved by the person in charge of site construction. When working on site, please pay attention to vehicle access and mechanical lifting. During normal construction, there should be no less than 2 people, and when there is only one person on site, no operation is allowed. Obey the instructions of on-site construction personnel, obey the assignment, unite and complete the production task. Materials on site shall be stacked neatly, and hazardous materials, chemical reagents and flammable materials must be placed separately. It is strictly prohibited to work in flammable and explosive places, open fire, smoking, etc. In operation major City circuit lamp Before that, please check whether the operation site is safe, whether the road is unblocked and whether the protective measures are complete. The tools used should be restored after the work is completed. Please wear safety belt when working at heights, cliffs and steep slopes without protective facilities.

 07.png

Science and technology lead energy conservation, and wisdom lights up life