The life of LED mining lamp depends largely on the level of heat dissipation, and the main way to improve the level of heat dissipation is to transfer the excess heat generated by the chip through the radiator and radiator. At the same time, major Municipal lighting The main parameters related to LED heat dissipation are thermal resistance, junction temperature, temperature rise, etc. Thermal resistance is the quotient obtained by dividing the difference between the effective temperature of the equipment and the temperature of the external designated reference point by the steady-state power consumption in the equipment. It is an important parameter indicating the degree of heat dissipation of equipment. Junction temperature refers to the temperature of the semiconductor junction of the main heating part in the LED device. It reflects major Municipal lighting Temperature value that can be withstood under working conditions. Temperature rise refers to the temperature rise of the enclosure environment. It refers to the difference between the temperature of LED equipment shell and the ambient temperature. This is a temperature value that can be directly measured, which can directly reflect the heat dissipation degree around LED devices.

LED garden lights are energy-saving and environmentally friendly. The main structure is an electroluminescent semiconductor diode, which has low luminous flux loss and long service life. According to the scientific research results of LED light source, major Municipal lighting Its service life is three times that of the basic light source and 30% that of the energy-saving street lamp. Power saving is equal to saving the investment in electricity costs, and it is also because LED courtyard lamps have their unique advantages, which can meet the requirements of today's society for energy conservation and environmental protection. courtyard major Municipal lighting The advantage of saving more electricity costs has a wide influence on the market. In order to improve people's quality of life, the street lamps that need to be used are energy-saving and environmentally friendly. Both specifications, lighting performance and lighting effect can meet the requirements of street lamp standards. Facing many LED garden lights with complex market environment, it is necessary to choose a good brand LED garden light manufacturer.

1. Be able to monitor the temperature of the light source chip pad of the street lamp itself or the temperature of the lamp shell and conduct fault diagnosis; 2. Remote measurement of electrical parameters such as street lamp current and voltage, remote switching of street lamps, remote viewing of on-site operation of important road sections, etc; 3. According to major Municipal lighting The monitoring data of can timely grasp the abnormal position and reason of street lights, and carry out purposeful maintenance without having to go to the whole city for inspection, which speeds up the speed. 4. It has daylight sensor or on-board sensor dimming, energy saving control, time control and even RTC dimming; 5. In some areas with few people and vehicles, it can be controlled at half bright time in the middle of the night, but when people and cars pass by, major Municipal lighting They will reach the distance ahead and in a few cases restore the original brightness. Seconds. 6. The lighting standard level of the same road will change with time and traffic flow.

Main pole of high pole lamp: major Municipal lighting When the height of the main pole exceeds 20m, the steel plate with a wall thickness of 5.6mm is usually used as the main material. After the overall welding of the high pole lamp, the internal and external surface layers need to be hot-dip galvanized and qualified galvanized. This process can ensure that the main pole will not rust for 15 years. Lifting system: the lifting system is regarded as the core part of the high pole lamp. The landing action of the light panel depends entirely on the landing system. The landing system of high pole lamp is mainly hoist and wire rope. First, install the elevator on the main rod. Weathering and rain will not cause line aging. Secondly, the hoist seldom starts. If major Municipal lighting If the light source has not been damaged in ten years, it will not need to be touched in ten years. Lamp cap: Whether it is LED lamp cap or low pressure sodium lamp, the light source is the main symbol of the whole set of high pole lamp. If the light source is broken and the high pole lamp is broken, the selection of light source quality is particularly important.

(1) Recommended installation height of 50W LED energy-saving mining lamp: 3-5 meters; Installation distance: 5-8m. (2) Recommended installation height of 100W LED energy-saving mining lamp: 6-8m; Installation distance: 8-10 m. (3) 120W LED energy-saving mining lamp Recommended installation height: 8-10m; Installation distance: 8-10 m. (4)150W major Municipal lighting Recommended installation height: 10-15m; Installation distance: 8-12m. (5) major Municipal lighting 200W Recommended installation height: 10-15m; Installation distance: 10-15m. (6) LED energy-saving mining lamp 300W recommended installation height: 15-20m; Installation distance: 20-25m. (7) Recommended installation height of 450W LED energy-saving mining lamp: 15-20m; Installation distance: 25-30m