The bulb shall be firm and upright and shall not be loose or skewed. If the enamel umbrella is corroded or deformed major Industrial lighting It needs to be replaced in time. Before using electric tools, please check whether the wiring, plug, socket, grounding and leakage protection devices are in good condition. Do not use them if they are damaged. Safety slogans, warning signs and safety operation instruction boards shall be set up on the construction site. Materials on the site shall be stacked orderly and stably and handled from top to bottom. When using hand-held electric tools, please wear personal protective equipment and the power cord should be empty. It is forbidden for non operators to use it on site major Industrial lighting Power switches, wires and various mechanical equipment. Outdoor construction is not allowed in rainy season. Outdoor construction should be carried out after the rain is dry. The Quality Safety Department is responsible for preparing labor protection articles to ensure the safety of construction personnel.

Main pole of high pole lamp: major Industrial lighting When the height of the main pole exceeds 20m, the steel plate with a wall thickness of 5.6mm is usually used as the main material. After the overall welding of the high pole lamp, the internal and external surface layers need to be hot-dip galvanized and qualified galvanized. This process can ensure that the main pole will not rust for 15 years. Lifting system: the lifting system is regarded as the core part of the high pole lamp. The landing action of the light panel depends entirely on the landing system. The landing system of high pole lamp is mainly hoist and wire rope. First, install the elevator on the main rod. Weathering and rain will not cause line aging. Secondly, the hoist seldom starts. If major Industrial lighting If the light source has not been damaged in ten years, it will not need to be touched in ten years. Lamp cap: Whether it is LED lamp cap or low pressure sodium lamp, the light source is the main symbol of the whole set of high pole lamp. If the light source is broken and the high pole lamp is broken, the selection of light source quality is particularly important.

1、 Disconnection. For "dead light", we should first determine major Industrial lighting Is it short circuit or open circuit. 2、 The adhesive layer is peeled off. For some LED energy-saving project lights with vertical chips, the common reasons for dead lights are the peeling off of the bottom of the chip bonding layer and the peeling off of the bracket coating. 3、 The welding spot is burnt. In some cases, the dead light of the bulb may not be caused by the bulb itself, but also by the power supply used. 4、 Chip corrosion. The previous energy-saving floodlights and energy-saving floodlights are open circuit. The following is the condition of short circuit dead light. major Industrial lighting There are many reasons for dead lights. Dead light may appear in every link from packaging, application to use.

With the emergence of high brightness white LED light source, it is possible to apply it in the lighting field. According to the prediction of international authoritative organizations, the 21st century will enter the era of new light sources represented by LED, that is, the fourth generation of new light sources. major Industrial lighting Its brightness is the same as that of traditional fluorescent lamps, and its color is gentle and easy to accept. The service life is 50000-80000 hours. When the bulb is started, it will open immediately and can be repaired when it is damaged (the traditional fluorescent lamp has been damaged and cannot be reused). It is not only very energy-saving, but also more environmentally friendly. major Industrial lighting It is one of the main products promoted by the national green lighting energy-saving project, and is currently the first choice to replace the traditional high-pressure sodium lamp for industrial and mining lamps. At present, LED mining lamp has been used in many industrial enterprises, and its application effect is well received by customers.

major Industrial lighting Coordination of color temperature and illuminance. The color temperature of light source is the color expression of light, major Industrial lighting The psychological effects of light color on people include cooling and heating effects and other expansion effects. The cooling and warming effect is based on the blue-green and red orange as the two extremes of "cold color" and "warm color". It is generally believed that red has a warm feeling, while cyan has a cold and muddy feeling. The color temperature should be selected to achieve the desired lighting effect as to what kind of nightscape environment atmosphere needs to be created. The influence of color temperature on people is not only the feeling of cold and warm, but also the environmental illuminance. At low illumination levels, warm light with low color temperature is more acceptable, while at higher illumination levels, cool light with higher color temperature is more popular.

install major Industrial lighting The construction site shall be provided with safety slogans, warning signs and safety operation instruction boards, which shall not be removed or moved at will. Any movement shall be approved by the person in charge of site construction. When working on site, please pay attention to vehicle access and mechanical lifting. During normal construction, there should be no less than 2 people, and when there is only one person on site, no operation is allowed. Obey the instructions of on-site construction personnel, obey the assignment, unite and complete the production task. Materials on site shall be stacked neatly, and hazardous materials, chemical reagents and flammable materials must be placed separately. It is strictly prohibited to work in flammable and explosive places, open fire, smoking, etc. In operation major Industrial lighting Before that, please check whether the operation site is safe, whether the road is unblocked and whether the protective measures are complete. The tools used should be restored after the work is completed. Please wear safety belt when working at heights, cliffs and steep slopes without protective facilities.