If there is a problem with the solar street lamp in the countryside, first check whether the photocell is correctly connected, whether the wiring position is in poor contact, and then check whether the battery connection is correct and whether the battery voltage is normal. If the battery is excessively discharged, a fault will occur and it will automatically recover after being fully charged. Among them, major Intelligent industrial lighting The stability of the controller is very important for the service life of rural solar street lights, because the role of the solar controller is to control the use major Intelligent industrial lighting The battery board charges and discharges the battery. When choosing a solar cell, you must choose a high stability battery to ensure the service life of the battery, because the quality of the battery will also directly affect the service life of the street lamp. It can extend the service life of the whole rural solar street lamp.

The working voltage of a single bulb for LED tunnel lighting is very low, about 3V, so the power consumption of a low-voltage working environment is half of the power required for the same strong light. The tunnel lamp has a long service life and does not need regular maintenance and inspection. After a period of use, the traditional major Intelligent industrial lighting The brightness of the tunnel lamp will be greatly reduced, but its attenuation is only 20% of that of the tunnel lamp. Moreover, the tunnel lamp is small in size and can be made into various shapes to adapt to various environments. The shell of the tunnel lamp is of integrated design, which is durable and not easy to be damaged. Each light source inside can be installed and removed separately, which is very convenient in the future maintenance process, and the overall design can ensure good heat dissipation effect. The heat dissipation rack inside the shell, the airflow and the heat emitted by the full contact with the air, effectively reduce the major Intelligent industrial lighting And prolongs the service life of the tunnel lamp.

Like the hump of a camel, the battery of a solar street lamp has the function of storing energy. The importance is self-evident. Third generation solar street lamp battery replacement, from lead-acid battery to gel battery to lithium battery. At present, the mainstream major Intelligent industrial lighting Battery has gradually developed from gel battery to lithium battery. Relatively speaking, colloidal battery has low price, relatively mature technology and high stability. advantage. The disadvantages are that compared with lithium batteries of the same level, the service life is relatively short, the electric energy storage capacity of the same volume is less, and there are other fatal disadvantages. Although the apparent price is a little expensive, the use cost is very low. Two years of poor use, we major Intelligent industrial lighting engineering The battery pack can be used for 8-10 years. Welcome new and old customers to call and write.

During use, the bulb will be hit by wind and rain, which may cause its angle deviation, thus affecting the lighting effect. If any deviation is found, it must be adjusted in time. Check the bulb surface regularly. If on major Intelligent industrial lighting Cracks found on the surface glass of the bulb may cause rainwater to enter the bulb, which will seriously affect the use effect and service life of the bulb. The bulb should be removed immediately and sent to the original factory for repair. Avoid all kinds of serious accidents, such as leakage. Clean the lamp regularly to maintain its brightness. Turn off the lamp before cleaning it major Intelligent industrial lighting The power supply of the lamp shall be cleaned with a dry cloth or dry cloth to prevent the lamp from being damp, let alone with chemical or corrosive substances. Otherwise, the bulb will be corroded, which may cause accidents.

fixed major Intelligent industrial lighting There are many methods, such as ceiling, embedded, hoisting (straight pipe or chain) and wall absorption. Generally, open lamps are usually used indoors. Enamel surface reflector shall be selected, with thick aluminum oxide film or aluminum reflector coated with silicon dioxide protective film. Movable local illuminators are equipped with corresponding handles, hooks, clamps, etc. Fixed local illuminators are usually firmly locked on the working machine by screws or fixing mechanisms. For large factories and large machine tool places requiring separate lighting major Intelligent industrial lighting Reflectors made of materials with strong light control characteristics, such as prismatic glass, mirror glass and polished aluminum, to obtain narrow beam distribution.

1、 Disconnection. For "dead light", we should first determine major Intelligent industrial lighting Is it short circuit or open circuit. 2、 The adhesive layer is peeled off. For some LED energy-saving project lights with vertical chips, the common reasons for dead lights are the peeling off of the bottom of the chip bonding layer and the peeling off of the bracket coating. 3、 The welding spot is burnt. In some cases, the dead light of the bulb may not be caused by the bulb itself, but also by the power supply used. 4、 Chip corrosion. The previous energy-saving floodlights and energy-saving floodlights are open circuit. The following is the condition of short circuit dead light. major Intelligent industrial lighting There are many reasons for dead lights. Dead light may appear in every link from packaging, application to use.