(1) Material requirements: an excellent energy-saving mining lamp is made of aluminum alloy with high thermal conductivity, and its surface is sprayed with anti-corrosion metal paint to ensure heat dissipation in the future. (2) Brightness requirements: according to different use environments major Floodlight There are high requirements for the brightness of. Generally, the power used in normal space and large shopping centers is mostly 50w-100w lumens above 3000, and the brightness of the lights is selected according to the size of the area. (3) Heat dissipation performance: the quality of LED energy-saving mining lamp radiator has a great impact on its quality. We produce major Floodlight The thickened and accurate automobile aluminum strong convection radiator is adopted, and the working mode is eddy current heat dissipation. The service life of the light source is largely guaranteed.

 Qingdao professional floodlight project

Considering that street lamps are conductors, one way is major Floodlight Combination of external lightning protection and internal lightning protection. As the material of street lamp is conductor, it is equivalent to lightning rod, and downlead and grounding grid need to be installed in the design. These systems constitute the external lightning protection system. After the completion of the external lightning protection system, the fire and personal safety accidents caused by the direct lightning stroke of the street lamp can be avoided. After the completion of external lightning protection, the internal lightning protection system can protect the equipment by grounding and setting voltage protection. major Floodlight The internal lightning protection system is ready to prevent induced lightning and other forms of overvoltage intrusion, which may damage the power supply. This is also beyond the protection of external lightning protection system. Therefore, the built-in internal protection and external protection can complement each other.

 Qingdao professional floodlight project

one major Floodlight The charging circuit adopts a dual MOS series control circuit, which can reduce the voltage loss of the circuit by nearly half compared with the use of diodes. The use of PWM energy-saving control greatly increases the power consumption. 2. The load mode adopts pure light control. When the light is dark, the light sensor system will automatically light up. 3. Scientific battery management method. When over discharge occurs, the battery voltage will promote charging. After maintenance and compensation, it can be used normally. Direct charging and floating charging are used to connect rechargeable batteries. 4. All restrictions of all industrial chips and closed components can operate normally in cold, high temperature and humid environments. At the same time, major Floodlight The use of crystal oscillator time control can make the time control more accurate.

 Qingdao professional floodlight project

(1) High light efficiency: the spectrum is almost all concentrated on the visible light frequency, and the efficiency can reach 80% - 90%. (2) High light quality: because there is no ultraviolet and infrared ray in the spectrum, there is no heat and radiation. This is a typical green light source. (3) Long life: the standard life is 40000 hours when the luminous flux decays to 70%. major Floodlight It can be used for 8 years under normal conditions. (4) Reliable and durable: there is no tungsten wire, glass and other easily damaged parts, the abnormal scrap rate is very small, and the maintenance cost is very low. (5) Flexible application: small size, flat packaging, easy to develop into light, thin, short products, can be made into various forms of dot, line, surface special products. (6) Green environmental protection: waste can be recycled without pollution, major Floodlight And unlike high-pressure mercury lamps, they contain mercury. (7) Very short response time: energy-saving ceiling lamp suitable for frequent switching and high-frequency operation.

 Qingdao professional floodlight project

1、 Disconnection. For "dead light", we should first determine major Floodlight Is it short circuit or open circuit. 2、 The adhesive layer is peeled off. For some LED energy-saving project lights with vertical chips, the common reasons for dead lights are the peeling off of the bottom of the chip bonding layer and the peeling off of the bracket coating. 3、 The welding spot is burnt. In some cases, the dead light of the bulb may not be caused by the bulb itself, but also by the power supply used. 4、 Chip corrosion. The previous energy-saving floodlights and energy-saving floodlights are open circuit. The following is the condition of short circuit dead light. major Floodlight There are many reasons for dead lights. Dead light may appear in every link from packaging, application to use.