Considering that street lamps are conductors, one way is major Plant light Combination of external lightning protection and internal lightning protection. As the material of street lamp is conductor, it is equivalent to lightning rod, and downlead and grounding grid need to be installed in the design. These systems constitute the external lightning protection system. After the completion of the external lightning protection system, the fire and personal safety accidents caused by the direct lightning stroke of the street lamp can be avoided. After the completion of external lightning protection, the internal lightning protection system can protect the equipment by grounding and setting voltage protection. major Plant light The internal lightning protection system is ready to prevent induced lightning and other forms of overvoltage intrusion, which may damage the power supply. This is also beyond the protection of external lightning protection system. Therefore, the built-in internal protection and external protection can complement each other.

1. When you buy back the LED ceiling lamp, please do not install it. Please read the label of the bulb carefully and read the installation manual, and then install and use the LED ceiling lamp according to the instructions, otherwise it may be dangerous. 2. Please be careful not to change it during cleaning and maintenance major Plant light Do not replace the parts of LED ceiling lamp at will. After cleaning and maintenance, install the bulb as it is, and do not omit or install the bulb components incorrectly; 3. Maintenance is required during use major Plant light To extend its service life. Wipe with dry cloth frequently, and pay attention to prevent moisture intrusion to avoid rust or long-term leakage and short circuit; Wipe as much as possible to avoid affecting light penetration.

one major Plant light The charging circuit adopts a dual MOS series control circuit, which can reduce the voltage loss of the circuit by nearly half compared with the use of diodes. The use of PWM energy-saving control greatly increases the power consumption. 2. The load mode adopts pure light control. When the light is dark, the light sensor system will automatically light up. 3. Scientific battery management method. When over discharge occurs, the battery voltage will promote charging. After maintenance and compensation, it can be used normally. Direct charging and floating charging are used to connect rechargeable batteries. 4. All restrictions of all industrial chips and closed components can operate normally in cold, high temperature and humid environments. At the same time, major Plant light The use of crystal oscillator time control can make the time control more accurate.

With the emergence of high brightness white LED light source, it is possible to apply it in the lighting field. According to the prediction of international authoritative organizations, the 21st century will enter the era of new light sources represented by LED, that is, the fourth generation of new light sources. major Plant light Its brightness is the same as that of traditional fluorescent lamps, and its color is gentle and easy to accept. The service life is 50000-80000 hours. When the bulb is started, it will open immediately and can be repaired when it is damaged (the traditional fluorescent lamp has been damaged and cannot be reused). It is not only very energy-saving, but also more environmentally friendly. major Plant light It is one of the main products promoted by the national green lighting energy-saving project, and is currently the first choice to replace the traditional high-pressure sodium lamp for industrial and mining lamps. At present, LED mining lamp has been used in many industrial enterprises, and its application effect is well received by customers.

install major Plant light The construction site shall be provided with safety slogans, warning signs and safety operation instruction boards, which shall not be removed or moved at will. Any movement shall be approved by the person in charge of site construction. When working on site, please pay attention to vehicle access and mechanical lifting. During normal construction, there should be no less than 2 people, and when there is only one person on site, no operation is allowed. Obey the instructions of on-site construction personnel, obey the assignment, unite and complete the production task. Materials on site shall be stacked neatly, and hazardous materials, chemical reagents and flammable materials must be placed separately. It is strictly prohibited to work in flammable and explosive places, open fire, smoking, etc. In operation major Plant light Before that, please check whether the operation site is safe, whether the road is unblocked and whether the protective measures are complete. The tools used should be restored after the work is completed. Please wear safety belt when working at heights, cliffs and steep slopes without protective facilities.

1. Be able to monitor the temperature of the light source chip pad of the street lamp itself or the temperature of the lamp shell and conduct fault diagnosis; 2. Remote measurement of electrical parameters such as street lamp current and voltage, remote switching of street lamps, remote viewing of on-site operation of important road sections, etc; 3. According to major Plant light The monitoring data of can timely grasp the abnormal position and reason of street lights, and carry out purposeful maintenance without having to go to the whole city for inspection, which speeds up the speed. 4. It has daylight sensor or on-board sensor dimming, energy saving control, time control and even RTC dimming; 5. In some areas with few people and vehicles, it can be controlled at half bright time in the middle of the night, but when people and cars pass by, major Plant light They will reach the distance ahead and in a few cases restore the original brightness. Seconds. 6. The lighting standard level of the same road will change with time and traffic flow.